Model |
ELSIS / “ELS-1K0-INV” ; “ELS-1K5-INV” ; “ELS-2K0-INV” |
Manufacturer |
ELSİS A.S. |
Output Power |
1000 / 1500 / 2000 VA; (under linear load) |
Input Voltage Range |
20 – 33 Vdc |
Ripple Reflected to Input |
Less than 200 mV rms |
DC Input Compatibility |
MIL-STD-1275B; (Bat. only, Gen. only, Bat.+ Gen.) |
Noise Reflected to Input |
Less than 500 mV (pp) under full load |
No-Load Power Dissipation |
Less than 80 W |
Input Protection |
Electronic shut-off when input voltage is out of operation range, and effective fuse protection against reverse battery connection. |
Output Voltage Stability |
220 Vac; +/-1% (can be tailored to customer request) |
Output Frequency and Stability |
50 Hz; +/-0,5% (can be tailored to customer request) |
Output Power Factor |
Full capacitive, resistive to full inductive |
Output Wave Form |
Sinusoidal |
Output THD |
Better than 3% at full load |
Crest Factor |
Better than 3:1 |
Allowable Over-Load |
Up to 2500 VA, for 2 seconds (the 1500 VA unit) |
DC Content On Output |
Less than 100 mV |
Output Protection and Current Limiting |
Full and continuous electronic protection against over-load and short-circuit (current limiting without distorting the output wave form); optional Thermal-Magnetic circuit-breaker |
Efficiency |
Above 87% under 50% to 100% linear load |
Electromagnetic Compatibility |
“MIL-STD-461E; CE101; CE102; RE101; RE102” |
Duration of Operation |
Continuous, 24 hours a day, 7 days a week |
Weight |
7,95 kg (apprx. 17 lb) |
Cooling |
Forced air cooling by an internal axial fan |
Mechanical Units |
Metric (can be modified to customer request) |
Dimensions |
W: 184 mm; H: 130 mm; D: 400 mm (Less handle bar & connectors) |
Front Panel Controls, Indicators and Rear Panel Connections |
Power On/Off switch, Power On LED, Fault “LED”, on the front panel; “MS-3102” circular connectors, T/M circuit breakers, and optional passive fuse on the rear panel |
Operation Ambient Temperature |
Between -32o C and +55o C |
Storage Ambient Temperature |
Between –40o C and +80o C |
Salt and Mist |
MIL-STD-810F Method 509.4 |
Mechanical Choke |
MIL-STD-810F, Method 516.5, Procedure 1- Functional Choke 40g, 11 ms, saw tooth on all axes, opposite directions, Military Land Vehicle |
Vibration |
MIL-STD-810F, Catagory 24, Procedure-1 (Annex A 2.4.1) minimum integrity on all axes, 1 hour each |
Acoustical Noise |
Less than 50 dB(A) |
Operation Altitude |
4000 m; above 4000 m according to degradation curve |
Relative Humidity |
Up to 90% (without condensation) |